English
heat pump
You are here: Home » Heat Pump » Commercial Hot Water Heat Pump » TENESUN R32 KFXRS-21IIBP/C1 Variable Frequency Low-Temperature Commercial Hot Water Heat Pump Unit (Air- Source Heat Pump)

loading

TENESUN R32 KFXRS-21IIBP/C1 Variable Frequency Low-Temperature Commercial Hot Water Heat Pump Unit (Air- Source Heat Pump)

TENESUN low-temperature commercial variable frequency heat pump water heater delivers 21kW rated heating capacity with a high COP of 4.73, reaching up to 60℃ hot water. Adopting R32 eco-friendly refrigerant and full DC inverter scroll jet enthalpy enhancement technology, it operates stably from -35℃ to 50℃. With intelligent frequency conversion throttling and high-efficiency anti-corrosion heat exchanger, it saves over 25% energy and extends service life by 20%. Suitable for residences, malls and hotels, it provides 24/7 stable hot water with flexible tank matching and space-saving outdoor installation.
Safe and reliable to ensure NO worry use.

Safety is top priority to the commercial hot water machines. TENESUN commercial hot water air source heat pumps adopt a closed design with complete separation of water and electricity and this completely eliminates safety risks such as electrical and water leakage. Furthermore, the machines are equipped with multiple safe protection measures, such as high and low pressure protection, compressor’s over-current and overload protection, start-up delay, water flow protection, water temperature’s high temperature protection and so on to ensure safe operation in any conditions. In addition, there is no need to use fuel delivery pipeline for TENESUN air source heat pumps and it will avoid the risks of fuel leaks, fire and explosion and there is no worry when use.
?
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button


Operating Instructions


  1. Before starting the unit, check the power supply, water system, and unit status to ensure there are no abnormalities;

  2. Start the unit and observe whether the operating parameters are normal;

  3. Adjust the water temperature as needed, but do not set the water temperature too low or too high;

  4. Regularly record operating data for maintenance and analysis purposes.


Precautions


  1. The installation location must be well-ventilated and protected from direct sunlight;

  2. Take necessary precautions against freezing in low-temperature environments during winter;

  3. Regularly clean the pipe filter and remove foreign objects from the external fins of the heat exchanger to maintain efficient operation;

  4. Non-professional person should not disassemble the unit without authorization;

  5. Drain the system of water when it is not in use for an extended period.


Proper operation and maintenance can extend the unit's lifespan and improve energy efficiency. Users should strictly follow the instructions in the manual and contact professional people immediately if any abnormalities occur.


ParameterValue
Rated heating capacity21kW (ambient temperature 20℃, inlet water temperature 15℃, outlet water temperature 55℃)
Input power4.441kW
COP4.73
Maximum outlet water temperature60℃, meeting the hot water needs of most environmental conditions
Compressorinternationally renowned brand variable frequency compressor
Heat exchangerindependently developed and manufactured high-efficiency heat exchanger, corrosion-resistant and scale-resistant, extending service life by 20%
Throttling technologyIntelligent variable frequency throttling technology automatically adjusts output power according to water volume, achieving energy savings of over 25%
Power supply specifications3-phase 380V/50Hz
Water flow rate3.6m3/h
Hot water production rate at normal temperature0.451 m3/h
Body size1000×390×930mm
Net weight232kg
Protection classIPX4


TENESUN low-temperature commercial heat pump water heater variable frequency unit uses R32 environmentally friendly refrigerant and full DC variable frequency scroll jet enthalpy enhancement technology, operating stably in an ultra-wide temperature range of -35℃ to 50℃. The intelligent control system can precisely regulate water temperature, suitable for various places such as residences, shopping malls, and hotels, providing a stable supply of hot water 24 hours a day. The high-efficiency heat exchange design improves the overall energy efficiency of the unit, reducing system energy consumption and costs. The water tank size can be flexibly matched to meet the hot water needs of commercial establishments of different sizes. It can be installed in outdoor open spaces, balconies, and other areas without occupying a large amount of space.




Previous: 
Next: 
Provide professional system energy solutions to customers and create value to them.

Heat Pump

Heat Pump Application

Copyright ? 2025 TENESUN Heat Pump All Rights Reserved. Sitemap. Privacy Policy.